Lightning Protection System

Fittings

One Hole Cable Clips (Solid Circular Conductor)

Brand:Kingsmill

One Hole Cable Clips:

CONDUCTOR DIA (mm)CONDUCTOR TYPEWEIGHT (kg)PART NO.QuantityAdd To Baskit
8.0Copper0.01OH8C
8.0Aluminium0.01OH8A
8.0Copper PVC Covered0.01OH10C
8.0Aluminium PVC Covered0.01OH10A

Use with Bare Stranded Copper Conductor:

CONDUCTOR CSA (mm²)CONDUCTOR DIA (approx mm)CONDUCTOR TYPEWEIGHT (kg)PART NO.QuantityAdd To Baskit
165.1Bare Stranded Copper0.020OH016
256.42Bare Stranded Copper0.020OH025
357.56Bare Stranded Copper0.020OH035
508.9Bare Stranded Copper0.020OH050
7010.7Bare Stranded Copper0.020OH070
9512.6Bare Stranded Copper0.022OH095
12014.21Bare Stranded Copper0.022OH120
15015.75Bare Stranded Copper0.025OH150
18517.64Bare Stranded Copper0.025OH185
24020.25Bare Stranded Copper0.027OH240
30022.68Bare Stranded Copper0.027OH300
40025.65Bare Stranded Copper0.032OH400

Use with PVC insulated Copper Cable:

CONDUCTOR CSA (mm²)CONDUCTOR DIA (approx mm)CONDUCTOR TYPEWEIGHT (kg)PART NO.QuantityAdd To Baskit
167.10PVC Insulated Copper Cable0.020OH016INS
258.90PVC Insulated Copper Cable0.020OH025INS
359.95PVC Insulated Copper Cable0.020OH035INS
5011.70PVC Insulated Copper Cable0.022OH050INS
7013.35PVC Insulated Copper Cable0.022OH070INS
9515.60PVC Insulated Copper Cable0.025OH095INS
12017.20PVC Insulated Copper Cable0.027OH120INS
15019.10PVC Insulated Copper Cable0.027OH150INS
18521.30PVC Insulated Copper Cable0.027OH185INS
24024.30PVC Insulated Copper Cable0.030OH240INS
30027.05PVC Insulated Copper Cable0.032OH300INS
40030.35PVC Insulated Copper Cable0.032OH400INS

Product Information:

One Hole Cable Clips are a simple solution for solid circular conductors to flat surfaces.

Features:

Material: Copper/Aluminium/High Copper Content Alloy

More Information:

When choosing a connector it is important to ensure:

  • The connector is mechanically robust.
  • The connector is selected according to its application.
  • The connector is rated for its application.

To avoid bimetallic corrosion-use a bimetallic connector (do not connect bare copper directly to bare aluminium, or have water run-off from copper, fall into aluminium).Galvanic corrosion happens when there is a potential difference between dissimilar metals:When the materials are in contact in the presence of an electrolyte, corrosion occurs. One metal becomes the anode, the other the cathode. The anode will tend to go into solution and therefore corrode. The electrolyte can be water with impurities from the air.In the instance of water run-off from copper- the water carries fine copper corrosion particles which, when they drop on to aluminium or zinc, may result in corrosion. The direct contact of the dissimilar metals are not required for corrosion to occur in such a case.