Galaxy-VM-200-kVA-UPS-Single-400-400-V-with-Backfeed-protection,-Start-up-5x8Galaxy-VM-200-kVA-UPS-Single-400-400-V-with-Backfeed-protection,-Start-up-5x8Galaxy-VM-200-kVA-UPS-Single-400-400-V-with-Backfeed-protection,-Start-up-5x8Galaxy-VM-200-kVA-UPS-Single-400-400-V-with-Backfeed-protection,-Start-up-5x8Galaxy-VM-200-kVA-UPS-Single-400-400-V-with-Backfeed-protection,-Start-up-5x8
Galaxy-VM-200-kVA-UPS-Single-400-400-V-with-Backfeed-protection,-Start-up-5x8

UPS (Uninterruptable Power Supply)

Three Phase UPS

Galaxy VM 200 kVA UPS Single 400 400 V with Backfeed protection, Start up 5x8

GVMSB200KHS

Brand:APC

Add Galaxy-VM-200-kVA-UPS-Single-400-400-V-with-Backfeed-protection,-Start-up-5x8 to Cart :

Lead timeUsually Ships within 2 Weeks

Main Input Voltage400 V 3 phases
Other Input Voltage380 V
415 V
Main Output Voltage400 V 3 phases
Other Output Voltage380 V
415 V
rated power in W180 kW
Rated power in VA200 kVA
Output connector typeHard wire 4-wire (3P + E) 1
Hard wire 5-wire (3P + N + E) 1
Battery typeExternal battery system
Provided equipmentBuilt-in modbus protocol adapter
Dust filter
Installation guide
Integrated network management
Seismic compliance
Top and bottom cable entry

Number of battery filled slots0
Battery voltage480 V
Discharge battery voltage384 V
Max current discharge393 A
Battery power in VAH0 VAh runtime
Extended runtime0

Bypass voltage tolerance+/- 10 % settable from +/- 4/6/8 and 10 %
Max bypass input current289 A
Bypass current protection400 A
RedundantNo

ColourWhite
Height197 cm
Width105.2 cm
Depth85.4 cm
Product weight724 kg
USB compatibleNo

Network frequency40...70 Hz
Input voltage limits250...600 V adjustable
320...456 V 380 V
320...480 V 400 V
320...498 V 415 V
Maximum input current328 A
Switching current capacity400 A
Max short time withstand current65 kA
Input harmonic distortionLess than 3 % for full load
Input protection typeGL fuse
Inrush current200 A peak
Load power factor0.5 leading to 0.5 lagging
Input Power Factor at Full Load1

Maximum configurable power in W180 kW
Harmonic distortionLess than 2 %
Output frequency50/60 Hz +/- 1 Hz sync to mains
50/60 Hz +/- 1 Hz unsynchronised
Crest factorUnlimited
Wave typeSine wave
Output voltage tolerance+/- 1% static and +/- 3% at 100% load step
Output harmonic distortion< 2% linear load and < 3% non-linear load
Output overload operation10 minutes at 125% and 60 seconds at 150%
Neutral output current289 A
bypass typeBuilt-in static bypass
Maximum configurable power in VA200 kVA

Product certificationsC-Tick
CE
RCM
standardsEN/IEC 62040-1
EN/IEC 62040-2
EN/IEC 62040-3
IBC 2012 and CBC2013 to Sds=2.02g
ISTA 2B
OSHPD
UL 1778

Ambient air temperature for operation0…40 °C
Relative humidity0…95 %
Operating altitude0...3333 ft
Ambient air temperature for storage-25…55 °C
Storage Relative Humidity0…95 %
Storage altitude0.00…14999.82 m
Acoustic level65 dBA
Heat dissipation24570 Btu/h
IP degree of protectionIP20

Free slots2
Control panel7 touch screen display
Emergency power offYes

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height215.6 cm
Package 1 Width106 cm
Package 1 Length149 cm
Package 1 Weight770 kg

Warranty1 year on-site repair or replace with factory authorized Start-Up